my combi boiler works fine at heating my water and filling radiators but every couple of weeks the pressure gauge goes down to 0 and i have to fill it up again. I can’t find leaks on the radiators ( also i live in an upstairs flat so i would have the women downstairs knocking if i did). I must admit i haven’t had the thing serviced for some time. also how much roughly does it cost to service a combi boiler?
Related posts:
- My combi boiler pressure has gone down below 1bar, no C/H but hot water. How can i build up d pressure?
Vaillant Turbomax 824E. Want to refill with water and build up the pressure. Any advice please?... - Combi Boiler Water Pressure Issues?
We recently had a combi boiler installed in our rented property. Initially the plumbers left the cold water feed from the tank in the loft so the combi boiler was only supplying the hot water. Unfortunately due to the differing pressures (i think), the cold water feed was excessive whilst using the shower the overflow pipe from the loft rained from the side of the house. The plumbers have since rectified that problem by removing the cold water tank and using the boiler to supply both the hot and cold. Unforunately the water pressure is now so low that it takes 30 mins to fill the bath. Also the shower now operates too hot and eventually (after a few mins) runs cold then hot again. Any help would be appreciated.... - Is a thermostatic mixer shower or electric better for combi boiler sytem with low pressure?
I intended to fit a thermostatic mixer shower with my new combi boiler heating system. However, the plumber has advised me that the water pressure I have is so low that the water flow would be poor and that for a more enjoyable shower an electric shower would be better. Is this correct? I have sought advice from various plumbers who all give different advice. Please help.... - Why does pressure of my combi boiler slowly keep going up to 3bar over a few days? It was ok when installed?
The bioler is Worcester 28CDI combi Fanned Flue RSF. The seals broke due to the 3bar pressure and was repaired by plumber. He said to bleed radiator to reduce pressure if it happens again, but this is a continual fault now.... - Why does my combi boiler pressure shoot up to 3bar?
I have a Baxi combi boiler (installed just over a year ago) and it has ran fine (opperating around 1.5-2bar) up until the 1 year warranty ran out (sods law!). Now when the system is off the pressure goes right down to 0bar. When I turn the heating on it goes up to 3bar. I have checked for leaks and bends/blocks in the flexi pipes (which there aren’t any) and also bled the system. When I turn the heating on (from 0bar pressure) the boiler makes cluncking sounds. Anyone have any ideas before I fork out a tonne for the plumbers? Thanks...








The water has to be escaping somewhere.
Have you checked the over pressure outlet pipe?
Sometimes if the pressure valve is made to work, it doesn’t quite seal again…
Have you seen the little pipe that goes outside, is it leaking slightly, if so then the pressure relief valve needs replacing.
You may well have a leak, over a couple of weeks may well not be noticeable.
Sometimes the pressure vessel needs recharging.
You should get your boiler serviced once a year. Have a look on Corgi’s website for an engineer near you
Aye. Sounds like that wee pipe that goes outside has a small leak on it – that’s the most likely, but you only need a very small leak of water to loose pressure and the leak could be evaporating on a hot pipe