<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: how do you drain and refill central heating which has a combi boiler?</title>
	<atom:link href="http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/</link>
	<description>Gas Boilers Information</description>
	<lastBuildDate>Wed, 16 Jul 2008 18:35:23 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: Belen Whitehurst</title>
		<link>http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/comment-page-1/#comment-543</link>
		<dc:creator>Belen Whitehurst</dc:creator>
		<pubDate>Sun, 06 Jul 2008 12:50:00 +0000</pubDate>
		<guid isPermaLink="false">http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/#comment-543</guid>
		<description>on one  of your downstairs radiators you should have a drain off    but if not just pop into b&amp;q they sell a self-cutting drain-off .connect a hose a discharge into a drain then open bleed vents from top rads down to lower rads then depending on your boiler it will either built in or seperate filling loop this refills the system .also boilers have built in air emittance valves you will here this hiss when filling no hiss check the cap is not screwed down dont for get  to add inhibitor go to wickes for this they sell it in a precharged can with conections for rads ect</description>
		<content:encoded><![CDATA[<p>on one  of your downstairs radiators you should have a drain off    but if not just pop into b&#038;q they sell a self-cutting drain-off .connect a hose a discharge into a drain then open bleed vents from top rads down to lower rads then depending on your boiler it will either built in or seperate filling loop this refills the system .also boilers have built in air emittance valves you will here this hiss when filling no hiss check the cap is not screwed down dont for get  to add inhibitor go to wickes for this they sell it in a precharged can with conections for rads ect</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Casey  Howells</title>
		<link>http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/comment-page-1/#comment-542</link>
		<dc:creator>Casey  Howells</dc:creator>
		<pubDate>Sun, 06 Jul 2008 01:54:52 +0000</pubDate>
		<guid isPermaLink="false">http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/#comment-542</guid>
		<description>You should have drain-offs on the lowest points of the central heating system so you just need to drain the system from these points. Make sure, whilst draining, you open the upstairs air vents to ensure ALL the water is drained from the system. Change the valve then add an inhibitor to the system. (to prevent corrosion/rusting) Re-fill the system via the filling loop, either under the boiler or actually built-in and bleed the radiators, most combination boilers will have an automatic air vent on so should release most of the air themselves. Let the system run and any air which the auto air vent hasn&#039;t released will circulate to the rads, you can bleed it yourself from here. Keep your eye on the pressure gauge on the boiler whilst bleeding cos the pressure will drop and you will need to keep topping it up. Hope this helps??



There are many different manufacturers of inhibitor, i generally either use Fernox or Sentinal, you can purchase the inhibitor either in a bottle or in what looks like a tube. Although these two types are in essence the same thing they can both be used in different ways. The one in a bottle is easier if you have an open vented system (the type with tanks in the loft) when you&#039;re re-filling this type of system you can add the &quot;bottle type&quot; directly to the small tank in the loft which is then added to the system as it fills.
When you&#039;ve got a sealed system (Combi system for example) things are a little more difficult and this is when the inhibitor in the tube comes in. There is less in the tube than there is in the bottle however it&#039;s concentrated gel type liquid so it is the equivalent of approximately one of the bottles. This maybe easier for you to use, and make sure the heating system is still drained when you add the inhibitor. With the tube type you&#039;ll need a silicon gun, insert the tube into the silicon gun and attach the radiator attachment which comes supplied with the inhibitor. Select a radiator (generally one upstairs is best) and, ensuring the system is still drained, you&#039;ll need to remove the air vent pin from the top of it. Once the air vent pin is removed you&#039;ll be able to insert the special attachment which came with the inhibitor into the tiny vent hole, with this done you can squeeze the trigger on the silicon gun thus adding the inhibitor. When the tube&#039;s empty the job&#039;s done, ensure you replace the vent pin and you can re-fill the system as i think i explained above. Hope this helps. Any problems call the number below.</description>
		<content:encoded><![CDATA[<p>You should have drain-offs on the lowest points of the central heating system so you just need to drain the system from these points. Make sure, whilst draining, you open the upstairs air vents to ensure ALL the water is drained from the system. Change the valve then add an inhibitor to the system. (to prevent corrosion/rusting) Re-fill the system via the filling loop, either under the boiler or actually built-in and bleed the radiators, most combination boilers will have an automatic air vent on so should release most of the air themselves. Let the system run and any air which the auto air vent hasn&#8217;t released will circulate to the rads, you can bleed it yourself from here. Keep your eye on the pressure gauge on the boiler whilst bleeding cos the pressure will drop and you will need to keep topping it up. Hope this helps??</p>
<p>There are many different manufacturers of inhibitor, i generally either use Fernox or Sentinal, you can purchase the inhibitor either in a bottle or in what looks like a tube. Although these two types are in essence the same thing they can both be used in different ways. The one in a bottle is easier if you have an open vented system (the type with tanks in the loft) when you&#8217;re re-filling this type of system you can add the &#8220;bottle type&#8221; directly to the small tank in the loft which is then added to the system as it fills.<br />
When you&#8217;ve got a sealed system (Combi system for example) things are a little more difficult and this is when the inhibitor in the tube comes in. There is less in the tube than there is in the bottle however it&#8217;s concentrated gel type liquid so it is the equivalent of approximately one of the bottles. This maybe easier for you to use, and make sure the heating system is still drained when you add the inhibitor. With the tube type you&#8217;ll need a silicon gun, insert the tube into the silicon gun and attach the radiator attachment which comes supplied with the inhibitor. Select a radiator (generally one upstairs is best) and, ensuring the system is still drained, you&#8217;ll need to remove the air vent pin from the top of it. Once the air vent pin is removed you&#8217;ll be able to insert the special attachment which came with the inhibitor into the tiny vent hole, with this done you can squeeze the trigger on the silicon gun thus adding the inhibitor. When the tube&#8217;s empty the job&#8217;s done, ensure you replace the vent pin and you can re-fill the system as i think i explained above. Hope this helps. Any problems call the number below.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Taryn Barton</title>
		<link>http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/comment-page-1/#comment-541</link>
		<dc:creator>Taryn Barton</dc:creator>
		<pubDate>Thu, 03 Jul 2008 11:55:44 +0000</pubDate>
		<guid isPermaLink="false">http://www.gasboilers.info/how-do-you-drain-and-refill-central-heating-which-has-a-combi-boiler/#comment-541</guid>
		<description>Turn the boiler off.  Look on the radiators and or pipework for a drain off valve and attach a hose pipe, then open drain valve.   once it is draining let air into the upstairs radiators via th vent .  To refill, close the drain valve, close all the rad vents and open the filling loop on, or near to the boiler and pressurise the system to 1-1.5 bar  then vent the radiators and re-pressurise. Do this until you have cleared the air from the rads then check the pressure again.  Keep your eye on the pressure for a couple of hours after the boiler has been running and top up as required.   Most combi boilers have a braided flexible hose which connects the cold water  to the heating system but some eg Worcester have a special plastic tap  which operates an internal filling loop, check the manual.. good luck</description>
		<content:encoded><![CDATA[<p>Turn the boiler off.  Look on the radiators and or pipework for a drain off valve and attach a hose pipe, then open drain valve.   once it is draining let air into the upstairs radiators via th vent .  To refill, close the drain valve, close all the rad vents and open the filling loop on, or near to the boiler and pressurise the system to 1-1.5 bar  then vent the radiators and re-pressurise. Do this until you have cleared the air from the rads then check the pressure again.  Keep your eye on the pressure for a couple of hours after the boiler has been running and top up as required.   Most combi boilers have a braided flexible hose which connects the cold water  to the heating system but some eg Worcester have a special plastic tap  which operates an internal filling loop, check the manual.. good luck</p>