<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: don&#8217;t have pressure in my natural gas boiler at home?</title>
	<atom:link href="http://www.gasboilers.info/dont-have-pressure-in-my-natural-gas-boiler-at-home/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.gasboilers.info/dont-have-pressure-in-my-natural-gas-boiler-at-home/</link>
	<description>Gas Boilers Information</description>
	<lastBuildDate>Wed, 16 Jul 2008 18:35:23 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: Zane  Normington</title>
		<link>http://www.gasboilers.info/dont-have-pressure-in-my-natural-gas-boiler-at-home/comment-page-1/#comment-110</link>
		<dc:creator>Zane  Normington</dc:creator>
		<pubDate>Wed, 28 May 2008 21:12:02 +0000</pubDate>
		<guid isPermaLink="false">http://www.gasboilers.info/dont-have-pressure-in-my-natural-gas-boiler-at-home/#comment-110</guid>
		<description>It seems that your boilers water pressure has dropped and when that happens, the boiler will automatically shut itself down.To refill the system, look under the boiler, and you should see a flexible pipe coming from the cold water supply which fills the boiler . You will find a tap of some sort on the flexible pipe close to the cold water supply. Open the tap and as the boiler refills, keep an eye on the water pressure gauge. When it gets up to one and a half bar, then stop filling.Too much water in the system will damage the expansion vessel that is built into the boiler.Your boiler should start up then. If you find that you are losing water from the boiler often, then it can be a faulty automic air vent, or a faulty pressure relief valve. Good luck.</description>
		<content:encoded><![CDATA[<p>It seems that your boilers water pressure has dropped and when that happens, the boiler will automatically shut itself down.To refill the system, look under the boiler, and you should see a flexible pipe coming from the cold water supply which fills the boiler . You will find a tap of some sort on the flexible pipe close to the cold water supply. Open the tap and as the boiler refills, keep an eye on the water pressure gauge. When it gets up to one and a half bar, then stop filling.Too much water in the system will damage the expansion vessel that is built into the boiler.Your boiler should start up then. If you find that you are losing water from the boiler often, then it can be a faulty automic air vent, or a faulty pressure relief valve. Good luck.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Ty  Challenger</title>
		<link>http://www.gasboilers.info/dont-have-pressure-in-my-natural-gas-boiler-at-home/comment-page-1/#comment-109</link>
		<dc:creator>Ty  Challenger</dc:creator>
		<pubDate>Wed, 28 May 2008 16:47:49 +0000</pubDate>
		<guid isPermaLink="false">http://www.gasboilers.info/dont-have-pressure-in-my-natural-gas-boiler-at-home/#comment-109</guid>
		<description>there must be aleak somewhere anyway to represurise boiler there is  apipe usualy flexible on the cold feed to boiler open valve at boiler end then valve atother end put 2 bar into sysem 30lbs then shut both valves  best of luck ps find the leak</description>
		<content:encoded><![CDATA[<p>there must be aleak somewhere anyway to represurise boiler there is  apipe usualy flexible on the cold feed to boiler open valve at boiler end then valve atother end put 2 bar into sysem 30lbs then shut both valves  best of luck ps find the leak</p>