<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Combi Boiler cuts out, what can the fault be?</title>
	<atom:link href="http://www.gasboilers.info/combi-boiler-custs-out-what-can-the-fault-be/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.gasboilers.info/combi-boiler-custs-out-what-can-the-fault-be/</link>
	<description>Gas Boilers Information</description>
	<lastBuildDate>Wed, 16 Jul 2008 18:35:23 +0000</lastBuildDate>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.1</generator>
	<item>
		<title>By: JaniyaW</title>
		<link>http://www.gasboilers.info/combi-boiler-custs-out-what-can-the-fault-be/comment-page-1/#comment-512</link>
		<dc:creator>JaniyaW</dc:creator>
		<pubDate>Fri, 06 Jun 2008 04:25:50 +0000</pubDate>
		<guid isPermaLink="false">http://www.gasboilers.info/combi-boiler-custs-out-what-can-the-fault-be/#comment-512</guid>
		<description>I dont know what u mean by engineers im guessing u mean plumbers but it sounds like to me thatr u dont have enough gas volume at the unit for it to ignite.....did u have anything on gas before this was added?.....also if u already had gas...did the installers size the line right to add that extra amount of BTU&#039;s that the unit would be pulling?.....theres alot of things that can go wrong with gas heaters,furnaces etc etc,....also the combi boiler sounds alot like a Rinnai water heater.....since it is still under warranty i would get the guy to come back out again and ask them to make sure there is enough gas volume going to the unit....they can test this using a manometer and see what the water column is.....thats what it sounds like to me is ur not getting enough gas to the unit</description>
		<content:encoded><![CDATA[<p>I dont know what u mean by engineers im guessing u mean plumbers but it sounds like to me thatr u dont have enough gas volume at the unit for it to ignite&#8230;..did u have anything on gas before this was added?&#8230;..also if u already had gas&#8230;did the installers size the line right to add that extra amount of BTU&#8217;s that the unit would be pulling?&#8230;..theres alot of things that can go wrong with gas heaters,furnaces etc etc,&#8230;.also the combi boiler sounds alot like a Rinnai water heater&#8230;..since it is still under warranty i would get the guy to come back out again and ask them to make sure there is enough gas volume going to the unit&#8230;.they can test this using a manometer and see what the water column is&#8230;..thats what it sounds like to me is ur not getting enough gas to the unit</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Meagan Arnold</title>
		<link>http://www.gasboilers.info/combi-boiler-custs-out-what-can-the-fault-be/comment-page-1/#comment-511</link>
		<dc:creator>Meagan Arnold</dc:creator>
		<pubDate>Thu, 05 Jun 2008 16:45:41 +0000</pubDate>
		<guid isPermaLink="false">http://www.gasboilers.info/combi-boiler-custs-out-what-can-the-fault-be/#comment-511</guid>
		<description>Could be any number of things.
Air intake restricted
Exhaust restricted.
Fan not operating correctly.
Flame sensor out of position.
Even a fault with the electronics.
Don&#039;t fiddle with it if is only 6 months old..
Still under warranty..
If you are not happy with the repair ask for it to be replaced.
if they don&#039;t...contact consumer rights</description>
		<content:encoded><![CDATA[<p>Could be any number of things.<br />
Air intake restricted<br />
Exhaust restricted.<br />
Fan not operating correctly.<br />
Flame sensor out of position.<br />
Even a fault with the electronics.<br />
Don&#8217;t fiddle with it if is only 6 months old..<br />
Still under warranty..<br />
If you are not happy with the repair ask for it to be replaced.<br />
if they don&#8217;t&#8230;contact consumer rights</p>